High-current nanosecond controlled multi-gap closing gap of radial design.
An experimental sample of a high-current nanosecond controlled multi-gap closing discharger of radial design directed to switching coaxial lines with charging voltage up to 400 kV was developed. Fig. 3 shows the design of the discharger. The outer diameter of the discharger is 200 mm, the length is 250 mm.
Fig. 3. Gas discharger of radial design.
1 - potential electrode, 2 - insulator, 3 - decoupling inductance, 4 - potential section of electrodes (capacitive chain), 5 - control section of electrodes (capacitive chain), 6 - control electrode, 7 - body.